- ; Windows Modem Setup File
- ; Copyright 1995 Microsoft Corp.
- ;
- ; Manufacturer: KORTEX International
- ;
-
-
- [Version]
- Signature="$CHICAGO$"
- Class=Modem
- Provider=%Mfg%
-
-
- [DestinationDirs]
- DefaultDestDir=17
- OldMdmKxInf=17
-
- [OldMdmKxInf]
- mdmnovfx.inf
- mdmkortx.inf
-
-
- [Manufacturer]
- %Mfg% = Models
-
- ; Modem models
-
- [Models]
- %Modem17% = Modem17, UNIMODEM906CB001
- %Modem16% = Modem16, UNIMODEMF65B52BD
- %Modem15% = Modem15, Kortex_Modem15
- %Modem14% = Modem14, UNIMODEMD05BA4A0
- %Modem13% = Modem13, UNIMODEM4F32C3DF
- %Modem12% = Modem12, UNIMODEMDD87DED1
- %Modem11% = Modem11, UNIMODEM25AB1772
- %Modem10% = Modem10, UNIMODEMA2712C92
- %Modem9% = Modem9, PCMCIA\RIPICAA-RC9624AC-7E29, UNIMODEMB596C5FA
- %Modem8% = Modem8, UNIMODEMA7A3B9D3, UNIMODEM39166726
- %Modem7% = Modem7, UNIMODEM36B6CC12
- %Modem6% = Modem6, PCMCIA\KORTEX_INTERNATIONAL-KXPRO_144_FAX-1181, PCMCIA\RIPICAA-RC144ACL-845A
- %Modem5% = Modem5, UNIMODEM26AC557F, UNIMODEMB99FCC34, UNIMODEM579B6B97, UNIMODEMC1B1FB3F, UNIMODEM7C1EE94E, UNIMODEM02CC60D0, UNIMODEMFF2B4678, UNIMODEMEC53C7D5
- %Modem4% = Modem4, UNIMODEM5F69F760, UNIMODEM628ED1C8, UNIMODEMA4C2E541, UNIMODEM2797756C
- %Modem3% = Modem3, PCMCIA\KORTEX_INTERNATIONAL-KXPRO_288_FAX-2A5D
- %Modem2% = Modem2, UNIMODEM3D6D197D, UNIMODEM42BA591B
- %Modem1% = Modem1, UNIMODEM1E7C5E3C
-
-
- ; Installation sections
-
- [Modem17] ; KORTEX NUMERIS 288 Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem17.AddReg, EXTERNAL
-
- [Modem16] ; KORTEX NUMERIS 288 Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem16.AddReg, INTERNAL
-
- [Modem15] ; KORTEX NUMERIS 144 Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem15.AddReg, EXTERNAL
-
- [Modem14] ; KORTEX NUMERIS 144 Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem14.AddReg, INTERNAL
-
- [Modem13] ; KORTEX NUMERIS Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem13.AddReg, EXTERNAL
-
- [Modem12] ; KORTEX NUMERIS Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem12.AddReg, INTERNAL
-
- [Modem11] ; KORTEX 2400 LECAM Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem11.AddReg, EXTERNAL
-
- [Modem10] ; KORTEX 2400 LECAM Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem10.AddReg, INTERNAL
-
- [Modem9] ; KORTEX 2400 PCMCIA
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem9.AddReg, PCMCIA
-
- [Modem8] ; KORTEX 2400 et MINITEL FAX Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem8.AddReg, EXTERNAL
-
- [Modem7] ; KORTEX 2400 et MINITEL FAX Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem7.AddReg, INTERNAL
-
- [Modem6] ; KORTEX 14400 PCMCIA
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem6.AddReg, PCMCIA
-
- [Modem5] ; KORTEX 14400 Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem5.AddReg, EXTERNAL
-
- [Modem4] ; KORTEX 14400 Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem4.AddReg, INTERNAL
-
- [Modem3] ; KORTEX 28800 PCMCIA
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem3.AddReg, PCMCIA
-
- [Modem2] ; KORTEX 28800 Externe
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem2.AddReg, EXTERNAL
-
- [Modem1] ; KORTEX 28800 Interne
- DelFiles=OldMdmKxInf
- AddReg=All, MfgAddReg, Modem1.AddReg, INTERNAL
-
-
- ; AddReg sections
-
- [Modem17.AddReg] ; KORTEX NUMERIS 288 Externe
- HKR,, Properties, 1, 00,00,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,05,00,00, 00,E1,00,00, 00,FA,00,00
- HKR,, FClass, 1, 07,00,00,00
- HKR, Init, 2,, "AT &O3<cr>"
- HKR, Init, 3,, "AT E0 S0=0 S95=45<cr>"
- HKR, Init, 4,, "AT &O6<cr>"
- HKR, Init, 5,, "AT S0=0 S95=45<cr>"
- HKR, Init, 6,, "AT &O7<cr>"
- HKR, Init, 7,, "AT S0=0 S95=45<cr>"
- HKR, Init, 8,, "AT &O1<cr>"
- HKR, Init, 9,, "AT S112=32<cr>"
- HKR, Init, 10,, "AT S111=7<cr>"
- HKR, Init, 11,, "AT S0=0 S95=45 \N3 %%C3<cr>"
- HKR, Init, 12,, "AT &O0<cr>"
- HKR, Hangup, 1,, "AT<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, DialSuffix,, ""
- HKR, Settings, Modulation_CCITT,, "B0 +MS=11,1,300,28800"
- HKR, Settings, Modulation_Bell,, "B1 +MS=11,1,300,28800"
- HKR, Settings, Modulation_CCITT_V23,, "B0 +MS=3,0,1200,1200"
- HKR, Fax, FixSerialSpeed,, "19200"
- HKR, Fax, FixModemClass,, "2"
- HKR, Fax, ResetCommand,, "AT S111=2"
- HKR, Fax, SetupCommand,, "AT E0 S0=0"
- HKR, Responses, "<cr><lf>CARRIER 64000<cr><lf>", 1, 01, 00, 00,FA,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: PAD<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: V.14<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 64000<cr><lf>", 1, 02, 00, 00,FA,00,00, 00,00,00,00
-
- [Modem16.AddReg] ; KORTEX NUMERIS 288 Interne
- HKR,, Properties, 1, 00,00,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,05,00,00, 00,C2,01,00, 00,FA,00,00
- HKR,, FClass, 1, 07,00,00,00
- HKR, Init, 2,, "AT &O3<cr>"
- HKR, Init, 3,, "AT E0 S0=0 S95=45<cr>"
- HKR, Init, 4,, "AT &O7<cr>"
- HKR, Init, 5,, "AT S0=0 S95=45<cr>"
- HKR, Init, 6,, "AT &O1<cr>"
- HKR, Init, 7,, "AT S112=32<cr>"
- HKR, Init, 8,, "AT S111=7<cr>"
- HKR, Init, 9,, "AT S0=0 S95=45 \N3 %%C3<cr>"
- HKR, Init, 10,, "AT &O0<cr>"
- HKR, Hangup, 1,, "AT<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, DialSuffix,, ""
- HKR, Settings, Modulation_CCITT,, "B0 +MS=11,1,300,28800"
- HKR, Settings, Modulation_Bell,, "B1 +MS=11,1,300,28800"
- HKR, Settings, Modulation_CCITT_V23,, "B0 +MS=3,0,1200,1200"
- HKR, Fax, FixSerialSpeed,, "19200"
- HKR, Fax, FixModemClass,, "2"
- HKR, Fax, ResetCommand,, "AT S111=2"
- HKR, Fax, SetupCommand,, "AT E0 S0=0"
- HKR, Responses, "<cr><lf>CARRIER 64000<cr><lf>", 1, 01, 00, 00,FA,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: PAD<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 64000<cr><lf>", 1, 02, 00, 00,FA,00,00, 00,00,00,00
-
- [Modem15.AddReg] ; KORTEX NUMERIS 144 Externe
- HKR,, Properties, 1, 00,00,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,05,00,00, 00,E1,00,00, 00,FA,00,00
- HKR,, FClass, 1, 0f,00,00,00
- HKR, Init, 2,, "AT &O3<cr>"
- HKR, Init, 3,, "AT E0 S0=0 S95=45<cr>"
- HKR, Init, 4,, "AT &O6<cr>"
- HKR, Init, 5,, "AT S0=0 S95=45<cr>"
- HKR, Init, 6,, "AT &O7<cr>"
- HKR, Init, 7,, "AT S0=0 S95=45<cr>"
- HKR, Init, 8,, "AT &O1<cr>"
- HKR, Init, 9,, "AT S112=32<cr>"
- HKR, Init, 10,, "AT S111=7<cr>"
- HKR, Init, 11,, "AT S0=0 S95=45 \N3 %%C3<cr>"
- HKR, Init, 12,, "AT &O0<cr>"
- HKR, Hangup, 1,, "AT<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, DialSuffix,, ""
- HKR, Fax, FixSerialSpeed,, "19200"
- HKR, Fax, FixModemClass,, "2"
- HKR, Fax, ResetCommand,, "AT S111=2"
- HKR, Fax, SetupCommand,, "AT E0 S0=0"
- HKR, Responses, "<cr><lf>CARRIER 64000<cr><lf>", 1, 01, 00, 00,FA,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: PAD<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: V.14<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 64000<cr><lf>", 1, 02, 00, 00,FA,00,00, 00,00,00,00
-
- [Modem14.AddReg] ; KORTEX NUMERIS 144 Interne
- HKR,, Properties, 1, 00,00,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,05,00,00, 00,C2,01,00, 00,FA,00,00
- HKR,, FClass, 1, 0f,00,00,00
- HKR, Init, 2,, "AT &O3<cr>"
- HKR, Init, 3,, "AT E0 S0=0 S95=45<cr>"
- HKR, Init, 4,, "AT &O7<cr>"
- HKR, Init, 5,, "AT S0=0 S95=45<cr>"
- HKR, Init, 6,, "AT &O1<cr>"
- HKR, Init, 7,, "AT S112=32<cr>"
- HKR, Init, 8,, "AT S111=7<cr>"
- HKR, Init, 9,, "AT S0=0 S95=45 \N3 %%C3<cr>"
- HKR, Init, 10,, "AT &O0<cr>"
- HKR, Hangup, 1,, "AT<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, DialSuffix,, ""
- HKR, Fax, FixSerialSpeed,, "19200"
- HKR, Fax, FixModemClass,, "2"
- HKR, Fax, ResetCommand,, "AT S111=2"
- HKR, Fax, SetupCommand,, "AT E0 S0=0"
- HKR, Responses, "<cr><lf>CARRIER 64000<cr><lf>", 1, 01, 00, 00,FA,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: PAD<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 64000<cr><lf>", 1, 02, 00, 00,FA,00,00, 00,00,00,00
-
- [Modem13.AddReg] ; KORTEX NUMERIS Externe
- HKR,, Properties, 1, 00,00,00,00, 00,00,00,00, 00,00,00,00, 00,00,00,00, 00,00,00,00, 10,00,00,00, 00,E1,00,00, 00,FA,00,00
- HKR,, FClass, 1, 00,00,00,00
- HKR, Init, 2,, "AT &O6<cr>"
- HKR, Init, 3,, "AT E0 S0=0 S95=45<cr>"
- HKR, Init, 4,, "AT &O7<cr>"
- HKR, Init, 5,, "AT S0=0 S95=45<cr>"
- HKR, Init, 6,, "AT &O1<cr>"
- HKR, Init, 7,, "AT S112=32<cr>"
- HKR, Init, 8,, "AT S0=0 S95=45<cr>"
- HKR, Hangup, 1,, "AT<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, DialSuffix,, ""
- HKR, Responses, "<cr><lf>CARRIER 64000<cr><lf>", 1, 01, 00, 00,FA,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: PAD<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: V.14<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 64000<cr><lf>", 1, 02, 00, 00,FA,00,00, 00,00,00,00
-
- [Modem12.AddReg] ; KORTEX NUMERIS Interne
- HKR,, Properties, 1, 00,00,00,00, 00,00,00,00, 00,00,00,00, 00,00,00,00, 00,00,00,00, 10,00,00,00, 00,C2,01,00, 00,FA,00,00
- HKR,, FClass, 1, 00,00,00,00
- HKR, Init, 1,, "AT &O7<cr>"
- HKR, Init, 2,, "AT E0 S0=0 S95=45<cr>"
- HKR, Init, 3,, "AT &O1<cr>"
- HKR, Init, 4,, "AT S112=32<cr>"
- HKR, Init, 5,, "AT S0=0 S95=45<cr>"
- HKR, Hangup, 1,, "AT<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, DialSuffix,, ""
- HKR, Responses, "<cr><lf>CARRIER 64000<cr><lf>", 1, 01, 00, 00,FA,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: PAD<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 64000<cr><lf>", 1, 02, 00, 00,FA,00,00, 00,00,00,00
-
-
- [Modem11.AddReg] ; KORTEX 2400 LECAM Externe
- HKR,, Properties, 1, 80,01,00,00, ff,00,00,00, ff,00,00,00, 07,00,00,00, 0f,00,00,00, b0,03,00,00, 80,25,00,00, 60,09,00,00
- HKR,, FClass, 1, 00,00,00,00
- HKR, Init, 2,, "AT Z<cr>"
- HKR, Init, 3,, "AT &F<cr>"
- HKR, Init, 4,, "AT E0 S0=0 T V1<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, Modulation_CCITT,, "F0"
- HKR, Settings, Modulation_Bell,, ""
- HKR, Settings, Modulation_CCITT_V23,, "F3"
-
- [Modem10.AddReg] ; KORTEX 2400 LECAM Interne
- HKR,, Properties, 1, 80,01,00,00, ff,00,00,00, ff,00,00,00, 07,00,00,00, 0f,00,00,00, b0,03,00,00, 80,25,00,00, 60,09,00,00
- HKR,, FClass, 1, 00,00,00,00
- HKR, Init, 2,, "AT Z<cr>"
- HKR, Init, 3,, "AT &F<cr>"
- HKR, Init, 4,, "AT E0 S0=0 T V1<cr>"
- HKR,, Reset,, "AT<cr>"
- HKR, Settings, Modulation_CCITT,, "F0"
- HKR, Settings, Modulation_Bell,, ""
- HKR, Settings, Modulation_CCITT_V23,, "F3"
-
- [Modem9.AddReg] ; KORTEX 2400 PCMCIA
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,4B,00,00, 60,09,00,00
- HKR,, FClass, 1, 0f,00,00,00
-
- [Modem8.AddReg] ; KORTEX 2400 et MINITEL FAX Externe
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,4B,00,00, 60,09,00,00
- HKR,, FClass, 1, 0f,00,00,00
-
- [Modem7.AddReg] ; KORTEX 2400 et MINITEL FAX Interne
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,4B,00,00, 60,09,00,00
- HKR,, FClass, 1, 0f,00,00,00
-
- [Modem6.AddReg] ; KORTEX 14400 PCMCIA
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,E1,00,00, 40,38,00,00
- HKR,, FClass, 1, 0f,00,00,00
-
- [Modem5.AddReg] ; KORTEX 14400 Externe
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,E1,00,00, 40,38,00,00
- HKR,, FClass, 1, 0f,00,00,00
-
- [Modem4.AddReg] ; KORTEX 14400 Interne
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,E1,00,00, 40,38,00,00
- HKR,, FClass, 1, 0f,00,00,00
-
- [Modem3.AddReg] ; KORTEX 28800 PCMCIA
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,C2,01,00, 80,70,00,00
- HKR,, FClass, 1, 0f,00,00,00
- HKR, Settings, Modulation_CCITT,, "B0 +MS=11,1,300,28800"
- HKR, Settings, Modulation_Bell,, "B1 +MS=11,1,300,28800"
- HKR, Settings, Modulation_CCITT_V23,, "B0 +MS=3,0,1200,1200"
-
- [Modem2.AddReg] ; KORTEX 28800 Externe
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,C2,01,00, 80,70,00,00
- HKR,, FClass, 1, 0f,00,00,00
- HKR, Settings, Modulation_CCITT,, "B0 +MS=11,1,300,28800"
- HKR, Settings, Modulation_Bell,, "B1 +MS=11,1,300,28800"
- HKR, Settings, Modulation_CCITT_V23,, "B0 +MS=3,0,1200,1200"
-
- [Modem1.AddReg] ; KORTEX 28800 Interne
- HKR,, Properties, 1, 80,01,00,00, FF,00,00,00, FF,00,00,00, 07,00,00,00, 0F,00,00,00, FF,07,00,00, 00,C2,01,00, 80,70,00,00
- HKR,, FClass, 1, 0f,00,00,00
- HKR, Settings, Modulation_CCITT,, "B0 +MS=11,1,300,28800"
- HKR, Settings, Modulation_Bell,, "B1 +MS=11,1,300,28800"
- HKR, Settings, Modulation_CCITT_V23,, "B0 +MS=3,0,1200,1200"
-
-
- ; User visible strings
-
- [Strings]
- ClassName = "Modem"
- Mfg = "KORTEX International"
-
-
- ; Model strings
-
- Modem17="KORTEX NUMERIS 288 Externe"
- Modem16="KORTEX NUMERIS 288 Interne"
- Modem15="KORTEX NUMERIS 144 Externe"
- Modem14="KORTEX NUMERIS 144 Interne"
- Modem13="KORTEX NUMERIS Externe"
- Modem12="KORTEX NUMERIS Interne"
- Modem11="KORTEX 2400 LECAM Externe"
- Modem10="KORTEX 2400 LECAM Interne"
- Modem9="KORTEX 2400 PCMCIA"
- Modem8="KORTEX 2400 et MINITEL FAX Externe"
- Modem7="KORTEX 2400 et MINITEL FAX Interne"
- Modem6="KORTEX 14400 PCMCIA"
- Modem5="KORTEX 14400 Externe"
- Modem4="KORTEX 14400 Interne"
- Modem3="KORTEX 28800 PCMCIA"
- Modem2="KORTEX 28800 Externe"
- Modem1="KORTEX 28800 Interne"
-
-
- ; --------------------------------------------------------------
- ; Common Registry Sections
-
- ; The [All] section is installed for all modems.
-
- [All]
- HKR,,FriendlyDriver,,unimodem.vxd
- HKR,,DevLoader,,*vcomm
- HKR,,PortSubClass,1,02
- HKR,,ConfigDialog,,modemui.dll
- HKR,,EnumPropPages,,"modemui.dll,EnumPropPages"
- HKR, Init, 1,, "AT<cr>"
- HKR, Responses, "<cr><lf>OK<cr><lf>", 1, 00, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>ERROR<cr><lf>", 1, 03, 00, 00,00,00,00, 00,00,00,00
-
- [EXTERNAL]
- HKR,, DeviceType, 1, 01
-
- [INTERNAL]
- HKR,, DeviceType, 1, 02
-
- [PCMCIA]
- HKR,,PortDriver,,Serial.vxd
- HKR,,Contention,,*vcd
- HKR,, DeviceType, 1, 03
-
-
- ; The [MfgAddReg] section contains the first modem's Init,
- ; Settings, and Responses keys. It is installed for all
- ; modems in the INF. This eliminates duplication of common
- ; registry keys in the model registry sections, above.
- ; To avoid as much duplication as possible, the first modem
- ; added to the INF should be the one with the most possible
- ; command/response strings.
-
- [MfgAddReg]
- HKR,, InactivityFormat,, "seconds"
- HKR, Init, 2,, "AT Z<cr>"
- HKR, Init, 3,, "AT &F<cr>"
- HKR, Init, 4,, "AT E0 S0=0 T V1 S95=45 \N3 %%C3<cr>"
- HKR, Monitor, 1,, "None"
- HKR, Hangup, 1,, "AT H<cr>"
- HKR, Answer, 1,, "AT A<cr>"
- HKR,, Reset,, "AT &F<cr>"
- HKR, Settings, Prefix,, "AT"
- HKR, Settings, Terminator,, "<cr>"
- HKR, Settings, DialPrefix,, "D"
- HKR, Settings, DialSuffix,, ";"
- HKR, Settings, SpeakerVolume_Low,, "L1"
- HKR, Settings, SpeakerVolume_Med,, "L2"
- HKR, Settings, SpeakerVolume_High,, "L3"
- HKR, Settings, SpeakerMode_Off,, "M0"
- HKR, Settings, SpeakerMode_Dial,, "M1"
- HKR, Settings, SpeakerMode_On,, "M2"
- HKR, Settings, SpeakerMode_Setup,, "M3"
- HKR, Settings, FlowControl_Off,, "&K0"
- HKR, Settings, FlowControl_Hard,, "&K3"
- HKR, Settings, FlowControl_Soft,, "&K4"
- HKR, Settings, ErrorControl_On,, "\N3"
- HKR, Settings, ErrorControl_Off,, "\N0"
- HKR, Settings, ErrorControl_Forced,, "\N2"
- HKR, Settings, Compression_On,, "%%C3"
- HKR, Settings, Compression_Off,, "%%C0"
- HKR, Settings, Modulation_CCITT,, "B0 F0"
- HKR, Settings, Modulation_Bell,, "B1 F0"
- HKR, Settings, Modulation_CCITT_V23,, "B0 F3"
- HKR, Settings, SpeedNegotiation_Off,, "N0"
- HKR, Settings, SpeedNegotiation_On,, "N1"
- HKR, Settings, Pulse,, "P"
- HKR, Settings, Tone,, "T"
- HKR, Settings, Blind_Off,, "X4"
- HKR, Settings, Blind_On,, "X3"
- HKR, Settings, Cellular_On,, ")M1"
- HKR, Settings, Cellular_Off,, ")M0"
- HKR, Settings, CallSetupFailTimer,, "S7=<#>"
- HKR, Settings, InactivityTimeout,, "S30=<#>"
- HKR, Fax, Class1DTESpeed,, "AUTO"
- HKR, Fax, Class1FlowOff,, "&K0"
- HKR, Fax, Class1FlowHW,, "&K3"
- HKR, Fax, Class1FlowSW,, "&K4"
- HKR, Fax, Class2FlowOff,, "&K0"
- HKR, Fax, Class2FlowHW,, "&K3"
- HKR, Fax, Class2FlowSW,, "&K4"
-
- HKR, Responses, "<cr><lf>RING<cr><lf>", 1, 08, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>NO CARRIER<cr><lf>", 1, 04, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>NO DIALTONE<cr><lf>", 1, 05, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>BUSY<cr><lf>", 1, 06, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>NO ANSWER<cr><lf>", 1, 07, 00, 00,00,00,00, 00,00,00,00
-
- HKR, Responses, "<cr><lf>CONNECT 0600<cr><lf>", 1, 02, 00, 58,02,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 1200<cr><lf>", 1, 02, 00, b0,04,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 2400<cr><lf>", 1, 02, 00, 60,09,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 4800<cr><lf>", 1, 02, 00, c0,12,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 9600<cr><lf>", 1, 02, 00, 80,25,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 7200<cr><lf>", 1, 02, 00, 20,1c,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 12000<cr><lf>", 1, 02, 00, e0,2e,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 14400<cr><lf>", 1, 02, 00, 40,38,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 19200<cr><lf>", 1, 02, 00, 40,38,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 38400<cr><lf>", 1, 02, 00, 40,38,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 57600<cr><lf>", 1, 02, 00, 00,e1,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 115200<cr><lf>", 1, 02, 00, 00,00,00,00, 00,c2,01,00
- HKR, Responses, "<cr><lf>CONNECT 16800<cr><lf>", 1, 02, 00, a0,41,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 21600<cr><lf>", 1, 02, 00, 60,54,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 24000<cr><lf>", 1, 02, 00, c0,5d,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 26400<cr><lf>", 1, 02, 00, 20,67,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 28800<cr><lf>", 1, 02, 00, 80,70,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 1200/75<cr><lf>", 1, 02, 00, 4b,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CONNECT 75/1200<cr><lf>", 1, 02, 00, 4b,00,00,00, 00,00,00,00
-
- HKR, Responses, "<cr><lf>DELAYED", 1, 03, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>BLACKLISTED<cr><lf>", 1, 03, 00, 00,00,00,00, 00,00,00,00
-
- HKR, Responses, "<cr><lf>CARRIER 300<cr><lf>", 1, 01, 00, 2c,01,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 1200/75<cr><lf>", 1, 01, 00, 4b,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 75/1200<cr><lf>", 1, 01, 00, 4b,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 1200<cr><lf>", 1, 01, 00, b0,04,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 2400<cr><lf>", 1, 01, 00, 60,09,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 4800<cr><lf>", 1, 01, 00, c0,12,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 7200<cr><lf>", 1, 01, 00, 20,1c,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 9600<cr><lf>", 1, 01, 00, 80,25,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 12000<cr><lf>", 1, 01, 00, e0,2e,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 14400<cr><lf>", 1, 01, 00, 40,38,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 28800<cr><lf>", 1, 01, 00, 80,70,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 16800<cr><lf>", 1, 01, 00, a0,41,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 19200<cr><lf>", 1, 01, 00, 00,4b,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 21600<cr><lf>", 1, 01, 00, 60,54,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 24000<cr><lf>", 1, 01, 00, c0,5d,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>CARRIER 26400<cr><lf>", 1, 01, 00, 20,67,00,00, 00,00,00,00
-
- HKR, Responses, "<cr><lf>COMPRESSION: CLASS 5<cr><lf>", 1, 01, 03, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>COMPRESSION: V.42BIS<cr><lf>", 1, 01, 03, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>COMPRESSION: NONE<cr><lf>", 1, 01, 00, 00,00,00,00, 00,00,00,00
-
- HKR, Responses, "<cr><lf>PROTOCOL: NONE<cr><lf>", 1, 01, 00, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: LAP-M<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: ALT<cr><lf>", 1, 01, 02, 00,00,00,00, 00,00,00,00
- HKR, Responses, "<cr><lf>PROTOCOL: ALT-CELLULAR<cr><lf>", 1, 01, 0a, 00,00,00,00, 00,00,00,00
-
- HKR, Responses, "0<cr>", 1, 00, 00, 00,00,00,00, 00,00,00,00 ; OK
- HKR, Responses, "2<cr>", 1, 08, 00, 00,00,00,00, 00,00,00,00 ; RING
- HKR, Responses, "3<cr>", 1, 04, 00, 00,00,00,00, 00,00,00,00 ; NO CARRIER
- HKR, Responses, "4<cr>", 1, 03, 00, 00,00,00,00, 00,00,00,00 ; ERROR
- HKR, Responses, "6<cr>", 1, 05, 00, 00,00,00,00, 00,00,00,00 ; NO DIALTONE
- HKR, Responses, "7<cr>", 1, 06, 00, 00,00,00,00, 00,00,00,00 ; BUSY
- HKR, Responses, "8<cr>", 1, 07, 00, 00,00,00,00, 00,00,00,00 ; NO ANSWER
-
-
-